PORTAFLOW PF333

PF333

PF333- Portable Ultrasonic Liquid Flow/ Heat Meter

Specification

Temperature sensors with PF333 energy meter.
Improved data logger logs energy and flow all date stamped.

Measurement Technique: Ultrasonic, cross-correlation transit time method for flow measurement and PT100 Class B 4 wire for temperature measurement.
Heat Meter Standard: The Heat/Energy calculation is designed to comply with EN1434 section 6.
Temperature sensors: Clamp-on PT100 Class B 4 wire, range 0°C – 200°C (32°F – 392°F), resolution 0.1°C (0.18°F). Minimum delta T is 0.3°C.
Carry Case: The PF333 is supplied in a hard wearing IP67 carry case.
‘A’ Transducers: 13mm OD to 115mm OD pipes.
‘B’ Transducers: 50mm OD to 2000mm OD pipes.
Transducer Operating Temp: ‘A’&‘B’ -20°C to +135°C. ‘A’&‘B’ Optional Hi-Temp -20°C to +200°C.
Turn Down Ratio: 100:1.
Data Communications: USB, supports most USB 2.0 BOM drives.
3 x Pulse Output: Pulse or Frequency. Opto-isolated MOSFET relay.
Max Current: 150mA. Isolation: >100V AC/DC. Pulse for volume flow and alarms, frequency for flow rate. The pulse outputs can be configured including: flow totals, energy, loss of signal, low flow alarms.
4-20mA Output: 4-20mA flow proportional output, optically isolated 1500 volts, 620 ohms maximum load.
Volumetric mode: Pulse repetition rates: up to 50 pulses/sec (depending on pulse width).
Frequency mode: Max. pulse frequency: 200Hz
Flow at max frequency: User selectable
Data Logging: 100,000,000 data points. 12 named sites. Download via USB to CSV file and export to Excel. Logs application details, time, date, flow rate, forward total, reverse total, flow velocity, flow side temperature, return side temperature, temperature difference, power, total energy, signal quality, signal SNR, signal status.

 

 

Industries

  • Water
  • Building Services
  • Energy Mangement
  • Power Generation
  • Chemical
  • Pharmaceutical
  • Petrochemical
  • Food

Recommended for:

  • Portable water
  • River water
  • Cooling water
  • Demineralised water
  • Water/glycol solutions
  • Hydraulic oil
  • Diesel and fuel oils
  • Chemicals
  • Petroleum products

Application/ use:

  • HVAC and energy system audits
  • Check system meters
  • Pump verification
  • Boiler testing
  • Leak detection
  • Filter sizing
  • Ultrapure water measurement
  • Heavy fuel oil metering
  • Condensate measurement
  • Balancing systems
  • Clean in place evaluation
  • Fire system testing
  • Hydraulic system testing

PORTAFLOW PF222

PF222

PF222- Portable Ultrasonic Liquid Flow/ Heat Meter

Specification

Now available with both A and B sensors.

Carry Case: Polypropylene case, with foam insert and double wall for extra strength.
PF222A with ‘A’ Transducers: 13mm OD to 115mm OD pipes.                                                                                                                                                                                                                PF222B with ‘B’ Transducers: 50mm OD to 1000mm OD pipes. Transducer Operating Temp: ‘A’& ‘B’ -20°C to +135°C.
Turn Down Ratio: 100:1.
3 x Pulse Output: Pulse or Frequency. Opto-isolated MOSFET relay. Max Current: 150mA. Isolation: >100V AC/DC. Pulse for volume flow and alarms, frequency for flow rate. The pulse outputs can be configured including: flow totals, loss of signal, low flow alarms.
4-20mA Output: 4-20mA flow proportional output, optically isolated 1500 volts, 620 ohms maximum load.
Volumetric mode: Pulse repetition rates: up to 50 pulses/sec (depending on pulse width).
Frequency mode: Max. pulse frequency: 200Hz.
Flow at max frequency: User selectable.

 

PF333 and PF222 Product Features

  • New cross correlation flow measurement system
  • Flow Range- 0.1m/sec to 20m/sec bi-directional
  • Display- 64 x 240 pixels graphic display
  • Set-up via 16 key control panel
  • Battery or mains operation
  • Rechargeable NiMH battery
  • Battery Life- 14 hours 2.5 hours charge time, depending on load
  • Power- 110-240VAC +/-10% supply via PSU
  • 4 user selectable languages including English, German, French and Spanish
  • Accuracy Pipe ID> 75mm -±0.5% to ±2% of flow reading for flow rate> 0.2m/s
  • Accuracy Pipe ID 13-75mm -±3% of flow reading for the flow rate
  • 0.2m/s
  • CEapproved
Portaflow Guide Dimensions

Hardware & Operation

The Portaflow electronics are housed in a specficially designed enclosure, which incorporates the graphic display, keypad, sensor and output facility connections. Set-up of the unit is carried out by selecting the options displayed in the main menu and by following the simple instructions in any of the user selectable languages.

The use of a rechargeable battery allows the unit to be operated for a period in excess of 14 hours depending on the facilities used. Continuous operation via the PSU is also possible while recharging the battery. Battery status, signal strength, time and date, as well as flow and energy information are all continuously displayed, keeping the user fully aware of the measurement process.

Hydronic Liquid Flow Energy Measurement

The PF333 is a portable, simple to use ultrasonic clamp-on flow and thermal, heat/energy meter, that uses ultrasound to measure flow rate and clamp-on PT100 temperature sensors to measure flow and return temperatures. The PF333 measures energy rate and totalised energy. And the Heat/Energy calculation is designed to comply with EN1434 section 6.

Flow Transducers

The Portaflow range is able to work with different transducer sets depending on the unit purchased and the application. Optional high temperature sensors are also available on the PF333. Sensor mounting clamps are provided with each instrument, to ensure correct mounting and reliable operation on any size pipe, in either diagonal or reflex modes.

Data Logger (PF333 only)

100,000,000 data points. 12 named sites. Download via USB to CSV file and export to Excel. Logs application details, time, date, flow rate, forward total, reverse total, flow velocity, flow side temperature, return side temperature, temperature difference, power, total energy, signal Quality, signal SNR, signal status.

 

 

BOOK A CONSULTATION

Call our Service Team today for a quote on: